All words in [xxx] are considered variables and require your input. * Solar absorption of reflective tinted glass requires one or both lites to be heat-treated. LE-GARDIEN MONOLITHIC REFLECTIVE GLASS* All reflective glass specified herein shall be Le-Gardiens reflective glass [LG-~~xxx] coating on [Colour] glass as supplied by Le-Gardien (S) Pte Ltd and be [Thickness]. The Unit Shall Have:
LE-GARDIEN INSULATING REFLECTIVE GLASS* All reflective insulating glass units specified herein shall be Le-Gardiens insulating reflective glass units as supplied by Le-Gardien (S) Pte Ltd. Insulating glass units shall consist of an interior lite of [Colour] glass [Thickness] thick, separated by a [Thickness] airspace, and an exterior lite of Le-Gardiens reflective glass [LG-??xxx] coating on [Colour] glass [Thickness]. The Unit Shall Have:
LE-GARDIEN SPANDREL REFLECTIVE GLASS* All reflective spandrel glass specified herein shall be Le-Gardiens spandrel reflective glass [LG-??xxx] coating on [Colour] glass as supplied by Le-Gardien (S) Pte Ltd and be [Thickness]. The product will have an [Opacifier film or Ceramic frit] of [Colour type] applied to the reflective surface.
LE-GARDIEN LAMINATED REFLECTIVE GLASS* All reflective laminated glass specified herein shall be Le-Gardiens laminated reflective glass. The laminated units shall consist of [Number] pieces of [Thickness, Clear or Colour , Treatment i.e. Annealed, Heat-strengthened or tempered], glass with [Number] interlayer [Thickness, Clear or Colour]. The reflective glass shall be Le-Gardiens reflective glass [LG-??xxx] coating on [Colour] glass as supplied by Le-Gardien (S) Pte Ltd and be [Thickness]. The Unit Shall Have:
LE-GARDIEN INSULATED LOW EMISSIVITY GLASS All low emissivity insulating glass units specified herein shall be Le-Gardiens Low-E insulating glass units as supplied by Le-Gardien (S) Pte Ltd. Insulated glass units shall consist of an interior/ exterior lite of [Colour] glass of [Glass Thickness], separated by a [Thickness] airspace, with an exterior/ interior lite of [LG-??xxx] on the [?__] surface on [Colour] glass and be [Thickness]. The Unit Shall Have:
LE-GARDIEN INSULATED GLASS UNITS All insulating glass units specified herein shall be Le-Gardiens insulating glass units as supplied by Le-Gardien (S) Pte Ltd. Insulating units shall consist of an interior lite of [Colour] glass [Glass Thickness], separated by a [Thickness] air space, with an exterior lite of [Colour] glass [Glass Thickness]. The Unit Shall Have:
SKYLIGHTS/ SLOPED GLAZING INSULATING AND LAMINATED GLASS UNITS All sloped glazing insulating glass specified herein shall be Le-Gardiens sloped glazing insulating and laminated glass as supplied by Le-Gardien (S) Pte Ltd. The construction shall consist of an exterior lite of [Colour] glass [Thickness, Clear, Colour or Reflective and Treatment], separated by a [Size] air space, with an interior lite of laminated glass consisting of [Number] pieces of glass [Thickness, Clear or Colour Treatment] with [Number] interlayer [Thickness, Clear or Colour]. Overall unit thickness shall be [Thickness].
SKYLIGHTS / SLOPED GLAZING LAMSAFE LAMINATED GLASS All sloped glazing laminated glass specified herein shall be Le-Gardien laminated glass as supplied by Le-Gardien (S) Pte Ltd. The construction shall consist of [Number] pieces of [Thickness, Clear or Colour Treatment] glass with [Colour] interlayer [Thickness, Clear or Colour]. Overall glass thickness shall be [Thickness].
LE-GARDIEN LAMINATED SAFETY GLASS All laminated glass specified herein shall be Le-Gardiens laminated glass as supplied by Le-Gardien (S) Pte Ltd. The construction shall consist of [Number] pieces of [Thickness, Clear or Colour, Treatment] glass with [Colour] interlayer [Thickness, Clear or Colour]. Overall glass thickness shall be [Thickness].
SOUND CONTROL GLASS All sound control laminated glass specified herein shall be Le-Gardien sound control glass as supplied by Le-Gardien (S) Pte Ltd. The construction shall consist of [Number] pieces of [Thickness, Clear or Colour, Treatment] glass with [Thickness, Clear or Colour] interlayer. For insulating units add: separated by a [Size] airspace, with an interior/ exterior lite of [Thickness, Clear or Colour, Treatment] glass. The glass unit shall have an STC value of (________).
HEAT PROCESSED GLASS All tempered or heat-strengthened glass specified herein shall be Le-Gardiens Heat Strengthened or Tempered glass as supplied by Le-Gardien (S) Pte Ltd. It shall be [Treatment, Thickness, Clear or Colour, and Size]. |